Change example conf file to use defaults ()

This commit is contained in:
Christian W. Zuckschwerdt 2023-10-18 11:54:42 +02:00
parent 138b389be3
commit 744c29a924

View file

@ -6,7 +6,8 @@
#
# Boolean options can be true/false, yes/no, on/off, enable/disable, or 1/0
#
# All options will be applied in the order given, overwriting previous values
# All options will be applied in the order given, overwriting previous values.
# Options given on the command line are then applied left to right.
#
# Config files can be nested/stacked (use multiple -c and config_file = ).
#
@ -36,14 +37,14 @@
# [-d "" Open default SoapySDR device
# [-d driver=rtlsdr Open e.g. specific SoapySDR device
# default is "0" (RTL-SDR) or "" (SoapySDR)
device 0
#device 0
# as command line option:
# [-g <gain>] (default: 0 for auto)
# For RTL-SDR: gain in tenths of dB ("0" is auto).
# For SoapySDR: gain in dB for automatic distribution ("" is auto), or string of gain elements.
# E.g. "LNA=20,TIA=8,PGA=2" for LimeSDR.
gain 0
#gain 0
# as command line option:
# [-t <settings>] apply a list of keyword=value settings for SoapySDR devices
@ -53,27 +54,27 @@ gain 0
# as command line option:
# [-f <frequency>] [-f...] Receive frequency(s) (default: 433920000 Hz)
# default is "433.92M", other reasonable values are 315M, 345M, 915M and 868M
frequency 433.92M
#frequency 433.92M
# as command line option:
# [-H <seconds>] Hop interval for polling of multiple frequencies (default: 600 seconds)
# default is "600" seconds, only used when multiple frequencies are given
hop_interval 600
#hop_interval 600
# as command line option:
# [-p <ppm_error] Correct rtl-sdr tuner frequency offset error (default: 0)
# default is "0"
ppm_error 0
#ppm_error 0
# as command line option:
# [-s <sample rate>] Set sample rate (default: 250000 Hz)
# default is "250k", other valid settings are 1024k, 2048k, 3200k
sample_rate 250k
#sample_rate 250k
# as command line option:
# [-D restart | pause | quit | manual] Input device run mode options.
# default is "quit"
device_mode quit
#device_mode quit
## Demodulator options
@ -115,7 +116,7 @@ pulse_detect magest
# as command line option:
# [-n <value>] Specify number of samples to take (each sample is 2 bytes: 1 each of I & Q)
samples_to_read 0
#samples_to_read 0
## Analyze/Debug options
@ -125,7 +126,7 @@ samples_to_read 0
# as command line option:
# [-A] Pulse Analyzer. Enable pulse analysis and decode attempt
analyze_pulses false
#analyze_pulses false
# as command line option:
# [-b] Out block size: 262144 (default)
@ -164,7 +165,7 @@ report_meta protocol
# as command line option:
# [-S none|all|unknown|known] Signal auto save. Creates one file per signal.
# Note: Saves raw I/Q samples (uint8 pcm, 2 channel). Preferred mode for generating test files.
signal_grabber none
#signal_grabber none
# as command line option:
# [-r <filename>] Read data from input file instead of a receiver
@ -229,7 +230,7 @@ convert si
# as command line option:
# [-E hop | quit] Hop/Quit after outputting successful event(s)
stop_after_successful_events false
#stop_after_successful_events false
## Protocols to enable (command line option "-R")