@ -0,0 +1,61 @@
|
|||
# Decoder for oma battery powered roller blind motor controller
|
||||
# Tested with blind motor with electronic limit switch. Mechanical limit
|
||||
# switch motors not tested.
|
||||
# Instructions (LKC040902 ver 1.0) reference motors C-C16/C-C17.
|
||||
|
||||
# The device tested is model 8C-C18-DC-WA-A101 5 channels
|
||||
# 433.92MHz
|
||||
# https://www.omaautomation.com/
|
||||
# FCC ID: Unknown
|
||||
|
||||
# Note. There is another controller of similar apearance, which has
|
||||
# programmable date/time functions, which uses a different (incompatable)
|
||||
# protocol.
|
||||
|
||||
# User manual: LKC040902 ver 1.0 (hardcopy)
|
||||
|
||||
# FCC ID: Unknown
|
||||
|
||||
# I have tested commands for blind up, blind stop and blind down.
|
||||
|
||||
# Short pulses have been found to work between 400 to 350 us, with long pulses
|
||||
# twice that.
|
||||
|
||||
# Schema of signal is <2 byte command>
|
||||
# <7 byte controller address>
|
||||
# <1 byte 1's compliment of channel number>
|
||||
# Up and down commands are sent as a pair of repeated commands.
|
||||
# Stop command is sent as a single repeated command.
|
||||
# The number of repeats received is quite variable, usually around 10.
|
||||
|
||||
# Channel number is 1's complement of the eigth byte. Thus 0xf = channel 0
|
||||
# 0xe = channel 1
|
||||
# ...
|
||||
# 0x0 = channel 15
|
||||
|
||||
# Up commands are:
|
||||
# Burst of about 6 repeats of: <ee><7 byte controler address><1 byte channel>
|
||||
# followed by a burst of about 6 repeats of: <e1><7 byte controler address><1 byte channel>
|
||||
|
||||
# Stop commands are:
|
||||
# Burst of about 6 repeats of: <aa><7 byte controler address><1 byte channel>
|
||||
|
||||
# Down commands are:
|
||||
# Burst of about 6 repeats of: <cc><7 byte controler address><1 byte channel>
|
||||
# followed by a burst of about 6 repeats of: <c3><7 byte controler address><1 byte channel>
|
||||
|
||||
decoder {
|
||||
n=oma,
|
||||
m=OOK_PWM,
|
||||
s=375,
|
||||
l=750,
|
||||
r=11760,
|
||||
g=0,t=0,
|
||||
y=4824,
|
||||
bits=40,
|
||||
rows>=2,
|
||||
get=command:@0:{8}:[238:up 225:up 170:stop 204:down 195:down],
|
||||
get=@8:{28}:controller_id,
|
||||
get=channel:@36:{4}:[15:0 14:1 13:2 12:3 11:4 10:5 9:6 8:7 7:8 6:9 5:10 4:11 3:12 2:13 1:14 0:15],
|
||||
unique
|
||||
}
|