# Equation/Siemens ADLM FPRF on 433.863MHz
|
||||
# 3 zones heater programer
|
||||
#
|
||||
# A 50ms wakeup pulse followed by a 5ms gap,
|
||||
# then a start pulse 5ms gap + 3ms pulse followed by 41 data pulses.
|
||||
# This is repeated 3 times with the next wakeup directly following
|
||||
# the preceding stop pulses.
|
||||
#
|
||||
# Bit width is 2000 us with
|
||||
# Short pulse: ___- 1500us gap + 500 us pulse
|
||||
# Long pulse: _--- 500us gap + 1500 us pulse
|
||||
#
|
||||
# This is a electric heater programmer sold in France by Leroy Merlin on the brand Equation.
|
||||
# It is manufactured by Siemens, and also has the mark RDE100.1 FPRF on the PCB
|
||||
|
||||
decoder {
|
||||
name=ADLM FPRF,
|
||||
modulation=OOK_PWM,
|
||||
short=500,
|
||||
long=1500,
|
||||
reset=7000,
|
||||
gap=2000,
|
||||
bits>=40,
|
||||
get=@8:{16}:id,
|
||||
get=@28:{4}:zone,
|
||||
get=@32:{4}:mode:[9:ECO 10:COMFORT 8:OFF],
|
||||
unique
|
||||
}
|